Rapid Pump Cessna Pump Repairs
Contact IAN on
07827 434777 |
- Check Oil Level in Reservoir:
- Fill to proper level.
- Check Hydraulic Fluid Specifications:
- Consult owner/operators manual for the proper type fluid.
- Inspect Inlet Screen or Strainer for:
- Suction screen or strainer plugged
- Suction line too small or too long
- Suction line collapsed or plugged.
- Inspect Compensator Signal for:
- Improper size or length of signal line.
- Damaged or obstructed signal line.
- *Inspect Pump Compensator for:
- Misadjusted pressure or flow setting.
- Pressure or flow spool stuck open.
- Pressure or flow spring weak or broken.
|